DESEMPENHO DE UM LISÍMETRO DE PESAGEM HIDRÁULICA COM SENSOR DE PRESSÃO HIDROSTÁTICA E SISTEMA MANOMÉTRICO

Autores

  • Nadielan da silva Lima Universidade Federal Rural de Pernambuco
  • Suzana Maria Gico Lima Montenegro Universidade Federal de Pernambuco
  • João Audifax Cézar de Albuquerque Filho Universidade Federal Rural de Pernambuco
  • Enio Farias França e Silva Universidade Federal Rural de Pernambuco
  • Abelardo Antônio de Assunção Montenegro Universidade Federal Rural de Pernambuco
  • Antônio Henrique Cardoso do Nascimento Universidade Federal Rural de Pernambuco

DOI:

https://doi.org/10.15809/irriga.2013v18n3p540

Resumo

1 RESUMO

Os lisímetros de pesagem hidráulica têm sido difundidos e aperfeiçoados para minimizar os problemas operacionais e apresentar boa precisão para detecção de mudanças de massa de água em condições de campo. Assim, objetivou-se construir, instalar e calibrar um lisímetro de pesagem hidráulica com um sensor de pressão hidrostática para automação das leituras, e analisar seu desempenho comparado ao tradicional sistema de leitura com pistão de mercúrio. O lisímetro constitui-se de um tanque interno em fibra de vidro com borda circular, possuindo área de 1,32 m² e volume de 1 m³, e um sistema de pesagem com três travesseiros hidráulicos flexíveis de butil-nylon de 100 mm de diâmetro.A calibração foi conduzida em recipientes de massa conhecida, representando uma faixa de variação de massa equivalente a 50 mm. Os resultados indicaram elevada linearidade entre as variações de massa e as respectivas leituras no sensor e manômetro. A precisão foi de 0,135 mm de ETo registrada pelo manômetro e de até 0,061 mm de ETo registrada pelo sensor, indicando que o sensor de pressão foi mais sensível as variações de massa do lisímetro. Os erros associados à histerese, estimativas de variação de massa e o erro médio posicional foram mais elevados no sistema manométrico.

 

Palavras-chave: evapotranspiração, coeficiente de calibração, lisimetria.

 

LIMA, N. S.; MONTENEGRO, S. M. G. L.; ALBUQUERQUE FILHO, J. A. C.; SILVA, E. F. F.; MONTENEGRO, A. A. A.; NASCIMENTO, A. H. C.

PERFORMANCE OF A HYDRAULIC WEIGHING LYSIMETER WITH A HYDROSTATIC PRESSURE SENSOR AND A MANOMETRIC SYSTEM

2 ABSTRACT

 

Hydraulic weighing lysimeters have been widely used   and improved to minimize operational problems, and provide good accuracy for detection of  changes in soil water content under field conditions. The objectives of this study were  to construct, install and  calibrate a hydraulic weighing lysimeter with a hydrostatic pressure sensor for automation of  readings, and analyze its  performance as compared to the traditional reading system with  mercury piston. The lysimeter consisted of a tank with internal glass fiber, circular edge area of 1.32 m² and volume of  1 m³, and a weighing system with three hydraulic flexible pillow of  butyl nylon 100 mm in diameter.

Calibration was conducted in known mass containers,  which represented a range of mass variation of 50 mm.  The results showed high linearity between mass variation and  the sensor and manometer readings.  Accuracy of 0.135 mm ETo  recorded by the pressure gauge and up to 0.061 mm ETo by the sensor showed  that the pressure sensor is more sensitive to mass variations  than the lysimeter. Errors associated with hysteresis, estimates of mass variation and the average positional error were higher in the manometric system.

 

Keywords: evapotranspiration, calibration coefficient, lysimeters.

Biografia do Autor

Nadielan da silva Lima, Universidade Federal Rural de Pernambuco

Departamento de Tecnologia Rural - Engenharia Agrícola

Suzana Maria Gico Lima Montenegro, Universidade Federal de Pernambuco

Departamento de Engenharia Civil

João Audifax Cézar de Albuquerque Filho, Universidade Federal Rural de Pernambuco

Departamento de Tecnologia Rural - Engenharia Agrícola

Enio Farias França e Silva, Universidade Federal Rural de Pernambuco

Departamento de Tecnologia Rural - Engenharia Agrícola

Abelardo Antônio de Assunção Montenegro, Universidade Federal Rural de Pernambuco

Departamento de Tecnologia Rural - Engenharia Agrícola

Antônio Henrique Cardoso do Nascimento, Universidade Federal Rural de Pernambuco

Departamento de Tecnologia Rural - Engenharia Agrícola

Downloads

Publicado

2013-08-22

Como Citar

LIMA, N. da silva; MONTENEGRO, S. M. G. L.; ALBUQUERQUE FILHO, J. A. C. de; SILVA, E. F. F. e; MONTENEGRO, A. A. de A.; NASCIMENTO, A. H. C. do. DESEMPENHO DE UM LISÍMETRO DE PESAGEM HIDRÁULICA COM SENSOR DE PRESSÃO HIDROSTÁTICA E SISTEMA MANOMÉTRICO. IRRIGA, [S. l.], v. 18, n. 3, p. 540–557, 2013. DOI: 10.15809/irriga.2013v18n3p540. Disponível em: https://irriga.fca.unesp.br/index.php/irriga/article/view/636. Acesso em: 28 mar. 2024.

Edição

Seção

Artigos