DESEMPENHO DO MEDIDOR ULTRASSÔNICO DE VAZÃO EM DIFERENTES TUBOS DE POLICLORETO DE VINILA

Autores

  • BRUNA DALCIN PIMENTA UNIVERSIDADE FEDERAL DE SANTA MARIA
  • ADROALDO DIAS ROBAINA UNIVERSIDADE FEDERAL DE SANTA MARIA
  • MARCIA XAVIER PEITER UNIVERSIDADE FEDERAL DE SANTA MARIA
  • JARDEL HENRIQUE KIRCHNER UNIVERSIDADE FEDERAL DE SANTA MARIA
  • WELLINGTON MEZZOMO UNIVERSIDADE FEDERAL DE SANTA MARIA
  • ROGÉRIO RICALDE TORRES UNIVERSIDADE FEDERAL DE SANTA MARIA

DOI:

https://doi.org/10.15809/irriga.2018v23n1p87

Resumo

DESEMPENHO DO MEDIDOR ULTRASSÔNICO DE VAZÃO EM DIFERENTES TUBOS DE POLICLORETO DE VINILA

 

 

BRUNA DALCIN PIMENTA1; ADROALDO DIAS ROBAINA1; MARCIA XAVIER PEITER1; JARDEL HENRIQUE KIRCHNER1; WELLINGTON MEZZOMO1 E ROGÉRIO RICALDE TORRES2

 

1Departamento de Engenharia Rural, Pós-Graduação em Engenharia Agrícola, Universidade Federal de Santa Maria, Av. Roraima, nº 1000, Bairro Camobi, 97105-900, Santa Maria, RS, Brasil. E-mail: brunadpimenta@gmail.com; diasrobaina@gmail.com; mpeiter@gmail.com; jardelkirchner@hotmail.com; wmezzomo@hotmail.com.

2Departamento de Ensino, Instituto Federal de Educação, Ciência e Tecnologia do Rio Grande do Sul, Rua João Viterbo de Oliveira, nº 3061, Zona Rural, 95200-000, Vacaria, RS, Brasil. E-mail: rogerio.torres@vacaria.ifrs.edu.br.

 

 

1 RESUMO

 

Os projetos relacionados à utilização ou manejo da água tem como ponto de partida a medida da vazão através de medidores específicos para sua mensuração. Um exemplo disso são os medidores de vazão ultrassônicos, os quais utilizam o método ultrassom e suas principais características são alta precisão e mobilidade, sendo de fácil utilização no meio urbano, industrial e rural. Este trabalho teve como propósito avaliar o desempenho de um medidor ultrassônico de vazão comparado com o método padrão hidrômetro, em diferentes tubos de PVC. O experimento foi realizado em um sistema de bombeamento de água em circuito fechado, no Laboratório de Hidráulica Agrícola da Universidade Federal de Santa Maria, RS. Foram utilizados tubos de PVC de distintas cores e utilizações, todos com 50 mm de diâmetro nominal e diferentes espessuras da parede. Foi atribuído o Índice de Desempenho e seu enquadramento em classes de desempenho, a fim de comparar os valores de vazão obtidos pelos dois métodos (ultrassônico e hidrômetro). Para os tubos de PVC branco e marrom, a classe de desempenho foi classificada como “Excelente”, enquanto que para o tubo de PVC azul foi “Bom”.

 

Palavras chave: condutos forçados, hidrometria, método ultrassom.

 

 

PIMENTA, B. D.; ROBAINA, A. D.; PEITER, M. X.; KIRCHNER, J. H.; MEZZOMO, W.; TORRES, R. R.

PERFORMANCE OF ULTRASONIC FLOW METER IN DIFFERENT VINYL POLYCHLORIDE PIPES

 

 

2 ABSTRACT

 

The projects related to the use or management of water have as starting point the measurement of flow through meters specific for their measurement. An example of this is the ultrasonic flowmeters, which use the ultrasound method and having as main characteristics high precision and mobility, being easy to use in urban, industrial and rural environments. The purpose of this work was to evaluate the performance of an ultrasonic flow meter compared to the standard hydrometer method in different PVC pipes. The experiment was carried out in a closed water pumping system at the Agricultural Hydraulics Laboratory of the Federal University of Santa Maria, RS. PVC tubes of different colors and uses were used, all with a nominal diameter of 50 mm and different wall thicknesses. The Performance Index and performance classes were assigned to compare the flow values obtained by the two methods (ultrasonic and hydrometer). For the white and brown PVC tubes, the performance class was rated "Excellent", while for the blue PVC pipe it was "Good".

 

Keywords: penstocks, hydrometric, ultrasound method.

Biografia do Autor

BRUNA DALCIN PIMENTA, UNIVERSIDADE FEDERAL DE SANTA MARIA

Engenheira Agrônoma, Doutoranda em Engenharia Agrícola. Área de concentração: engenharia de água e solo. Departamento de Engenharia Agrícola.

ADROALDO DIAS ROBAINA, UNIVERSIDADE FEDERAL DE SANTA MARIA

Engenheiro Agrônomo, Doutor em Engenharia Civil, área de concentração Hidráulica e Saneamento, Professor titular.

MARCIA XAVIER PEITER, UNIVERSIDADE FEDERAL DE SANTA MARIA

Engenheira Agrônoma, Doutora em Engenharia Civil, área de concentração Hidráulica e Saneamento, Professora Associada.

JARDEL HENRIQUE KIRCHNER, UNIVERSIDADE FEDERAL DE SANTA MARIA

Engenheiro Agrônomo, Doutorando em Engenharia Agrícola, área de concentração Engenharia de água e solo.

WELLINGTON MEZZOMO, UNIVERSIDADE FEDERAL DE SANTA MARIA

Engenheiro Agrônomo, Doutorando em Engenharia Agrícola, área de concentração Engenharia de água e solo.

ROGÉRIO RICALDE TORRES, UNIVERSIDADE FEDERAL DE SANTA MARIA

Engenheiro Agrônomo, Doutorando em Engenharia Agrícola, área de concentração Engenharia de água e solo, Professor.

Downloads

Publicado

2018-03-30

Como Citar

PIMENTA, B. D.; ROBAINA, A. D.; PEITER, M. X.; KIRCHNER, J. H.; MEZZOMO, W.; TORRES, R. R. DESEMPENHO DO MEDIDOR ULTRASSÔNICO DE VAZÃO EM DIFERENTES TUBOS DE POLICLORETO DE VINILA. IRRIGA, [S. l.], v. 23, n. 1, p. 87–95, 2018. DOI: 10.15809/irriga.2018v23n1p87. Disponível em: https://irriga.fca.unesp.br/index.php/irriga/article/view/2258. Acesso em: 28 mar. 2024.

Edição

Seção

Artigos