ENTUPIMENTO DE GOTEJADORES EM DECORRÊNCIA DE PULSOS DE PARTÍCULAS SÓLIDAS NA MALHA HIDRÁULICA

Autores

  • Rubens Duarte Coelho Unesp-FCA-Botucatu-SP
  • Luiz Artur Alvarenga Vilela
  • Ronaldo Souza Resende
  • Marconi Batista Teixeira
  • Jocelito Sacol de Sá

DOI:

https://doi.org/10.15809/irriga.2007v12n1p108-122

Resumo

ENTUPIMENTO DE GOTEJADORESEM DECORRÊNCIA DE PULSOSDE PARTÍCULAS SÓLIDAS NA MALHA HIDRÁULICA

 

 

Rubens Duarte Coelho1; Luiz Artur Alvarenga Vilela2; Ronaldo Souza Resende1; Marconi Batista Teixeira1; Jocelito Sacol de Sá1

1Departamento de Engenharia Rural, Escola Superior de Agricultura Luiz de Queiroz, Universidade de São Paulo, Piracicaba, SP, rdcoelho@esalq.usp.br

2In memorian

 

 

1 RESUMO

 

Ruptura de tubulações em sistemas de irrigação resulta, inevitavelmente, na entrada de partículas sólidas do solo, as quais podem entupir gotejadores. Em experimento realizado em condições de laboratório, foi avaliada a sensibilidade de cinco modelos de gotejadores ao entupimento de causa física, através da simulação de pulso de sujeira com solo, em função do tempo de operação, da posição de instalação do gotejador na linha terciária e da textura do solo. Os resultados demonstraram ser o fator posição de instalação do emissor de maior preponderância em relação a fatores de textura do solo e tempo de operação. Os modelos Ram e Tiran apresentaram menor sensibilidade ao pulso, enquanto os modelos Streamline, Dripline e Typhoon mostraram desempenho inferior.

 

UNITERMOS: obstrução física, gotejamento, pulso de sujeira

 

COELHO, R. D.; VILELA, L. A. A.; RESENDE, R. S.; TEIXEIRA, M.B.; SÁ, J. S. de. DRIP CLOGGING BY DIRTINESS PULSE OCCURRENCE

 

 

2 ABSTRACT

 

An experiment was conducted at The Laboratory of Irrigation in The Department of Rural Engineering, ESALQ, USP,Piracicaba-SP,Brazil, in order to evaluate different dripper designs for physical clogging potential to dirtiness pulse by soil intake in pipeline. System operation time, emitter connection point and soil texture were evaluated. The results showed that emitter connection point was more sensitive to plugging potential than soil texture and system operation time. There were significant differences among emitter models in relation to clogging potential. Ram andTiranmodels had better performance than Streamline, Dripline and Typhoon ones.

 

KEYWORDS: physical plugging, drip irrigation, dirtiness pulse

Downloads

Publicado

2007-03-27

Como Citar

COELHO, R. D.; VILELA, L. A. A.; RESENDE, R. S.; TEIXEIRA, M. B.; SÁ, J. S. de. ENTUPIMENTO DE GOTEJADORES EM DECORRÊNCIA DE PULSOS DE PARTÍCULAS SÓLIDAS NA MALHA HIDRÁULICA. IRRIGA, [S. l.], v. 12, n. 1, p. 108–122, 2007. DOI: 10.15809/irriga.2007v12n1p108-122. Disponível em: https://irriga.fca.unesp.br/index.php/irriga/article/view/3291. Acesso em: 27 abr. 2024.

Edição

Seção

Artigos