AVALIAÇÃO DE DANOS QUÍMICOS EM MEMBRANAS DE COMPENSAÇÃO DE GOTEJADORES, CAUSADO PELA APLICAÇÃO DINÂMICA DE DOSE EXTREMA DE CLORO LIVRE (Parte I)

Autores

  • Marconi Batista Teixeira Unesp-FCA-Botucatu-SP
  • Rubens Duarte Coelho
  • Ralini Ferreira de Melo

DOI:

https://doi.org/10.15809/irriga.2008v13n3p392-410

Resumo

AVALIAÇÃO DE DANOS QUÍMICOS EM MEMBRANAS DE COMPENSAÇÃO DE GOTEJADORES, CAUSADO PELA APLICAÇÃO DINÂMICA DE DOSE EXTREMA DE CLORO LIVRE (Parte I)

  Marconi Batista Teixeira; Rubens Duarte Coelho; Ralini Ferreira de Mélo

Departamento de Engenharia Rural, Área: Irrigação e Drenagem, Escola Superior de Agricultura Luiz de Queiroz, Universidade de São Paulo, Piracicaba, SP, marconi@esalq.usp.br

 

 

1 RESUMO

 

Com o propósito de avaliar a susceptibilidade de membranas de compensação de pressão de 14 modelos de gotejadores autocompensantes ao processo de dano químico, causado pela aplicação dinâmica de 100 mg L-1 de cloro livre, foi conduzido um experimento no Laboratório de Irrigação do Departamento de Engenharia Rural da Escola Superior de Agricultura “Luiz de Queiroz” – ESALQ/USP. Semanalmente foi feita a coleta de água utilizando o método gravimétrico por um período de dez min para todos os emissores presentes na linha gotejadora de cada um dos modelos estudados. Ocorreu um decréscimo de 10 a 20% em média da vazão (L h-1) para a maior parte dos emissores, com exceção do modelo E que apresentou aproximadamente 90% de redução de vazão (13% de aumento de volume da membrana) com 2688 h de funcionamento e redução drástica de vazão na ordem de 100% em virtude do bloqueio total do orifício para o emissor I, em decorrência do aumento de 112% do volume da membrana após 2688 h de aplicação dinâmica de 100 mg L-1 de cloro livre com pH na faixa de5,5 a 6,0.

 

UNITERMOS: cloração, elastômero, entupimento de emissores.

 

 

TEIXEIRA , M. B.; COELHO, R. D.; MÉLO, R. F. de. EVALUATION OF CHEMICAL DAMAGES ON SELF-COMPENSATING DRIPPER MEMBRANE, CAUSED BY DYNAMIC APPLICATION OF EXTREME DOSE OF FREE CHLORINE (PART I)

 

 

2 ABSTRACT

 

In order to evaluate the chemical resistance of 14 compensating emitters to the dynamic application of 100 mg L-1 of free chlorine, an experiment was carried out under laboratory conditions at the University of São Paulo, Brazil. Emitter flow was weekly evaluated using the gravimetric method. Later on, it was calculated: average flow rate (qm), and percentage of emitters according to flow rate reduction. An average reduction from 10 to 20% of the flow rate (L h-1) for most of the emitters was observed, except for the model “E” that presented approximately 90% of flow rate reduction (13% of increase of volume of the membrane) in 2688 h of operation and drastic reduction of flow rate of 100% (total clogging) for emitter model “I” , due to the increase of 112% membrane volume after 2688 h of dynamic application of 100 mg L-1 of chlorine free with pH 5.5 to 6.0.

KEY WORDS: chlorination, elastomer, emitter clogging.

Downloads

Publicado

2008-09-19

Como Citar

TEIXEIRA, M. B.; COELHO, R. D.; MELO, R. F. de. AVALIAÇÃO DE DANOS QUÍMICOS EM MEMBRANAS DE COMPENSAÇÃO DE GOTEJADORES, CAUSADO PELA APLICAÇÃO DINÂMICA DE DOSE EXTREMA DE CLORO LIVRE (Parte I). IRRIGA, [S. l.], v. 13, n. 3, p. 392–410, 2008. DOI: 10.15809/irriga.2008v13n3p392-410. Disponível em: https://irriga.fca.unesp.br/index.php/irriga/article/view/3379. Acesso em: 27 abr. 2024.

Edição

Seção

Artigos